Skip to content

PHI redaction

PHI redaction is an optional setting that masks patient data when your staff browse messages through an OpenShare remote admin connection. This page says what it masks, how it works and what it leaves untouched, so you can decide how to use it.

Redaction applies to message content in the remote message browser, including search results.

  • Message content is reduced to its structure. Segment and field names, message flow and status stay visible. The values are masked.
  • HL7 v2 messages keep a short list of non-patient fields visible for troubleshooting: message type, control IDs, and coded observation and order identifiers. Every other field is masked by default.
  • Map variables are blanked, both names and values.
  • Common identifiers are masked in any text that is still shown: email addresses, formatted Social Security numbers, phone numbers and card numbers.

Your organization owner can extend this in the organization’s Security settings:

  • Additional masked fields hides more HL7 fields, for example PID-8.
  • Custom masking patterns masks your own identifier formats, such as a medical record number, in the text that is still shown.
  • Masking happens on your server. The OpenShare plugin on your engine masks the content before it leaves, so the unmasked values are never sent to the browser.
  • Your organization owner sets the policy. When the organization requires redaction, each server’s own switch is locked on and can’t be turned off from the server.
  • A server that can’t redact is refused. If a server’s plugin is too old to apply redaction, remote admin connections to it are denied until the plugin is updated.

Redaction is a display control for the remote message browser. It does not change what your engine stores or sends.

  • Other remote views are shown as they are: the Dashboard’s Server Log, Connection Log and Global Maps, and the Events page.
  • Custom metadata columns are not masked as fields. The masking patterns catch some values, but a name or a numeric identifier in a column can show in full.
  • Study search results are not masked. Query and retrieve results list the patient and study details the remote system returns.
  • Text outside the masked fields relies on patterns. A name, address or free-text note in a field that is still shown is masked only if a built-in or custom pattern matches it.
  • Direct connections are not affected. Someone who connects straight to your own server, for example with the desktop Administrator, sees everything they always could.
  • Messages exchanged with your partners are not changed. Redaction never alters what your channels send or receive.

Redaction helps limit what remote staff see. It is not a compliance guarantee, and meeting HIPAA and your other obligations remains your organization’s responsibility.

Organization owners set redaction on the organization’s Security tab. See Security controls for the settings and Messages for what redacted messages look like.